분석&측정장비  |  Inorganic Analysis


ICP/MSNexion2200


모델명 : Nexion2200     / 제조사 : PerkinElmer


ICP/MS (Inductively Coupled Plasma-Mass Spectrometer)

 플라즈마를 이용하여 이온을 생성시키고, 생성된 이온들을 질량 필터를 통하여 검출하는 정성, 정량 분석용 무기원소 분석 장비


[Model : Nexion2200]

The NexION 2200 ICP-MS boasts a unique combination of proprietary technologies:

  • Three quadrupoles:
    • Quadrupole Ion Deflector (Q0) directs ions to the Universal Cell (Q1) with varied voltages, so target ion sensitivity is maximized while unwanted masses are reduced.
    • Quadrupole Universal Cell (Q1) uses up to three gases with on-the-fly gas mixing capability for Collision or Reaction modes. The unique quadruple cell is empowered by dynamic bandpass tuning, preventing reaction by-products from causing interferences with target analytes.
    • Transmission Analyzer Quadrupole (Q2, full-sized for < 0.7 amu mass resolution) acts as a mass filter or as an ion guide to direct ions to the detector.
  • Second-generation Triple Cone Interface with patent-pending OmniRing™ technology delivers unprecedented flexibility to handle a variety of applications without needing different inserts or lenses, as on other commercial ICP-MS systems, allowing three modes of operation, as needed.
  • Proprietary Extended Dynamic Range (EDR) increases linear dynamic range to 1014, allowing to run both high- and low-concentration analytes in a single analytical run, resulting in fewer re-runs.
  • Powerful All Matrix Solution (AMS) allows online gas dilution, improving efficiency and preventing contamination, delivering up to 200x dilution and the ability to support samples with up to 35% total dissolved solids.
  • Novel free-running RF Generator with proprietary LumiCoil™ RF load coil, especially designed for ICP-MS applications, provides accurate impedance matching to easily handle the most difficult matrices and solvents. This revolutionary combination delivers superior plasma power and stability for uncompromised performance, robustness, and reliability.
  • Low maintenance for greater uptime:
    • Triple Cone Interface and Quadrupole Ion Deflector combination deliver no maintenance beyond cones, for continual operation and improved stability.
    • 34 MHz free-running RF Generator offers trouble-free user experience – the plasma is generated by the unique LumiCoil RF load coil, which does not require water or gas cooling, so maintenance-free, eliminating need to replace plasma load coils.
  • Innovative LCD touchscreen allows you to perform critical day-to-day tasks, including hardware control, results reviews, instrument parameter diagnostics, analytics, access embedded training videos, and more.
  • External status LED lighting provides easy visibility of state of analysis, optimizing efficiencies in the laboratory.
  • Syngistix™ for ICP-MS software features a modern, intuitive user interface that mimics a typical daily workflow with left-to-right navigation and a streamlined experience.